| Place of Origin |
Shanghai China (Mainland) |
| Insulation Material |
PVC |
F multicore prefabricated branch cable armor This product is suitable for AC 50Hz, rated voltage 0.6/1kV the lines for the transmission and distribution electric energy. Model specifications are: common type, crosslinking type, flame retardant, fire resistant, safe and clean type, flame retardant fire resistant oxygen barrier. Maximum cable cross-section of up to: 240mm2 / phase; branch sections according to user requirements. VV 4-core PVC insulated PVC sheathed power cable parameters (0.6/1kv) Nominal conductor cross section size (mm2)Insulation thickness (mm)Sheath thickness (mm)Approximate diameter (mm)Approximate weight (kg/km)20 ° C conductor resistance Ω/kmRated current AVoltage drop(mV/m)40 °C in air30 °C in air4×1011.818.66821.835260844×1611.820.810101.157080694×251.21.824.714110.72788101564×351.21.927.118350.524110126504×501.41.928.224350.387133153454×701.42.23232710.268170196394×951.62.336.743380.193207238364×1201.62.54353830.153240276324×1501.82.647.767120.124277319304×18522.852.782070.0991316364284×2402.2359.4108500.0754374430254×3002.43.265.2136470.060143249723 VV 4+1-core PVC insulated PVC sheathed power cable parameters (0.6/1kv) Nominal conductor cross section size (mm2)Insulation thickness (mm)Sheath thickness (mm)Approximate diameter (mm)Approximate weight (kg/km)20 ° C conductor resistance Ω/kmRated current AVoltage drop(mV/m)40 °C in air30 °C in air4×10+1×611.8187201.835260844×16+1×1011.920.710551.157080694×25+1×161.21.924.615780.72788101564×35+1×161.21.926.819880.524110126504×50+1×251.42.128.526830.387133153454×70+1×351.42.230.636090.268170196394×95+1×501.62.434.748360.193207238364×120+1×701.62.538.160550.153240276324×150+1×701.82.742.673840.124277319304×185+1×9522.947.489110.0991316364284×240+1×1202.23.153.2114140.075437443025 YJV XLPE insulated PVC sheathed power cable 3 +1 core parameters (0.6/1kv) Nominal conductor cross section size (mm2)Insulation thickness (mm)Sheath thickness (mm)Approximate diameter (mm)Approximate weight (kg/km)20 ° C conductor resistance Ω/kmRated current AVoltage drop(mV/m)40 °C in air30 °C in air3×10+1×60.7/0.71.816.45031.836875843×16+1×100.7/0.71.818.57271.1591100693×25+1×160.9/0.71.822.310920.727116127563×35+1×160.9/0.71.824.814760.524144158503×50+1×251.0/0.91.825.919070.387174192453×70+1×351.1/0.91.929.926120.268224246393×95+1×501.1/1.02.133.734890.193271298363×120+1×701.2/1.12.237.544480.153315346323×150+1×701.4/1.12.341.653830.124363399303×185+1×951.6/1.12.546.767110.0991415456283×240+1×1201.7/1.22.751.985610.0754490538253×300+1×1501.8/1.42.957110800.0601565620